P-Series Specification |
|
|
| |
Standard
|
Option
|
| Type |
Cage Induction |
Slip Ring |
| Frame Sizes |
450 to 1400 |
|
| Output |
Up to 20000kW @ 4-pole speed |
|
| Voltage |
3150 to 13800V |
Others |
| Mounting |
Horizontal or Vertical |
|
| Frequency |
50Hz or 60Hz |
Variable Frequency Supply |
| Poles |
2 to 16 |
Others, Multiple-pole |
| Cooling |
CacA (TEAac) CacW (TEWac) |
Open Ventilated NEMA I or II |
| Ingress Protection |
IP55 |
IP22 to IP 56 |
| Mounting (EN 60034-7) |
IM1001, IM7011 & IM7211, IM3011 |
Others |
| Temperature Rise |
Class B |
Class F |
| Duty |
S1 |
Others |
| Insulation |
Class F, VPI |
Class H, VPI |
| Bearings |
Grease Lubricated, Rolling Element Bearings |
Oil - Lubricated Sleeve Bearings (Standard on some sizes) |
| Main Terminal Box |
Air Insulated for fused supplies Or Elastomeric termination |
Phase Insulated, Phase Segregated, BEAMA/CEGB, Others |
| Ambient Temperature |
-20OC to +40OC |
-50OC to +60OC |
| Starting |
Design N |
Design D, Low Starting Current, High Starting Torque |
| Starting Method |
DOL |
Others |
| Noise Level, Mean Sound Pressure Level, @ 1m, No Load |
81 dB(A) |
Refer to manufacturer for lower noise level. |
| Vibrations |
Grade R to EN60034.14 |
API 541 Ed 3 |
| Standards |
EN60034-1, IEC 72: Pt 2 |
NEMA MG1, Customer Specific |
| Area Classification |
Safe Area |
EEx n to EN50014/21, EEx e to EN50014/19, EEx p to En50014/16 |