| Standard | Option | |
| Type | Cage Induction | - |
| Frame Sizes | 315 to 630 | - |
| Output | 75 - 2500kW @ 4-pole speed | |
| Voltage | 3300, 4160, 6600 | Other voltages to 11kV |
| Mounting | Horizontal or Vertical | - |
| Frequency | 50Hz or 60Hz | Variable Frequency Supply |
| Poles | 2 to 8 | Others, Multiple-pole |
| Cooling | Air Cooled | - |
| Ingress Protection | IP44 | IP56 |
| Mounting (EN 60034-7) | IM2001 - Horizontal Foot, IM3011 - Vertical Flange | IM2001 - Horz. Foot and Flange, IM3811 - Vertical Skirt |
| Temperature Rise | Class B | Class F |
| Duty | S1 | Others |
| Insulation | Class F, VPI | Class H, VPI |
| Bearings | Grease Lubricated, Rolling Element Bearings | Oil - Lubricated, Rolling Element Bearings |
| Main Terminal Box | Phase Insulated (EEx e) | Phase Segregated (EEx d), Elastomeric termination (EEx e) |
| Ambient Temperature | -30OC to +55OC | Please refer to manufacturer. |
| Starting | Design N | Design D, Low Starting Current, High Starting Torque |
| Starting Method | DOL | Others |
| Noise Level, Mean Sound Pressure Level, @ 1m, No Load | 85 dB(A) | Refer to manufacturer for lower noise level. |
| Vibrations | Grade R to EN60034.14 | API 541 Ed 3 |
| Standards | EN60034-1, IEC 72: Pt 2 | NEMA MG1, Customer Specific |
| Area Classification | EEx d to EN50.018, for group IIA & IIB. | Group IIC Gases, Australian standards, AS2380: Pt 1: 1989, AS2380: Pt 2: 1991 |